EnglishTraditional Chinese
WORLDWIDE
Facebook
Twitter
YouTube
Skype
Florex Insulation
  • Company Profile
  • Product
    • Colex Insulation Material
      • COLEX Insulation Sheets
      • COLEX Insulation Sleeves
      • PE Foam Tape
      • PE Foam Profile
      • EVA foam Tape
    • Florex Pipe Support
    • Electronic Descaler
    • Nano Photocatalyst
    • Thermal Pad
    • Water Treatment Chemicals
  • Application
    • Electronic Descaler
      • Video
      • Institution
      • Hotel
      • Frozen Factory
      • Industry
      • Laser Cutting Factory
      • Plastic Product Factory
    • COLEX Insulation Sleeves
      • Cold Insulation of COLEX Insulation Sleeve in refrigerant food plant (-50°C)
      • Cryogenic Pipeline -40°C Liquid Ammonia pipeline
      • Liquid Nitrogen Pipeline(-196°C)
      • Failure Examples without Polyethylene foam material
    • COLEX Insulation Sheets
      • Petrochemical Storage Tank
      • Refrigerating Warehouse (-40°C)for seafood
      • Roof Insulation
      • Low Receiver Insulation
    • Florex Pipe Support
  • Installation
    • Colex Insulation Sleeves
    • Colex Insulation Sheets
    • Florex Pipe Support
  • Contact Us
  • News

Colex Insulation Sleeves & Sheets

2018-12-05productflorex
p_161031_07854p_161031_07875p_161031_07881

Colex Insulation Sleeves & Sheets

 

 Description
The polyethylene foam insulation sleeve and sheets are able to be applied on extreme low temperature, which is the excellent choice of building materials.

COLEX Foam is made from polyethylene, cross-linkage agent and foaming agent in high temperature and pressure. The closed cell foam structure renders it resilient and does not absorb water. The structure of COLEX Foam is chemical bond and each micro foam cell is strictly bonded. Because of this strong chemical bond, our foam insulation productions have contained good physical properties, such as flexible, compressible and chemical resistance against acid & alkali. This foam production also impacts absorbing and thus can protect objects and personnel.

Even under the pure oxygen or in utmost low temperature (-196°C) for a long time, the chemical bond of COLEX Foam will not be degraded. It is suitable in all situation for insulation in a temperature range between 80°C and -196°C. COLEX Foam has the excellent character of floating ability on the water. Even thrust by sharp material, it will not reduce its floating strength. It is therefore very suitable for applying on the vessel and floating material.

ssleevescolex1ssheet

Major Use:

  1. Construction insulation: Liquid Nitrogen pipelines and equipment, Liquid Ammonia pipelines and equipment, Liquid Ammonia refrigeration system, brine water pipelines of plant, raw material pipelines, and equipment of refinery and petrochemical plant, storage tanks.
  2. Air Conditioning insulation: chilling water pipelines, chillers, and ducts of air conditioner, etc.
  3. Building improvements: solar water heater insulation, cold and hot water pipeline insulation, corrugated steel
  4. Sound Isolation and Absorption: Engine room, engines, delivery and drainage pipelines
  5. Others: package, fishery, agriculture, toys, sports equipment, etc.

Easy Application:
COLEX foam material can be shaped by cutting, trimming, compression molding, and gluing. It can be stuck on every kind of metal surface by an adhesive.

Example of application:
Low receiver insulation on tank and pipelines in Food Plant

cc01cc02cc03cc04
Video:
Cold Insulation Construction of Chiller Plant

 

CHARACTER COLEX UNIT
DENSITY 0.021~0.027 g/㎝³
TENSILE STRENGTH 1.7 Min. kgf/㎝²
COMPRESSION SET 8 Max. %
DIMENSIONAL CHANGE AFTER HEATING  (75°C, 22hrs) ±5 Max. %
WATER ABSORPTION 0.01 Max. g/㎝³
COMBUSTIBILITY SELF EXTINGUISH
THERMAL CONDUCTIVITY 0.034 Max. kcal/m.hr.°C

Thickness Requirement for Pipe Insulation:

OUTDOOR OF CONDITION O.D. (PIPE) Skin Temp. of metal surface
60°C 15°C 10°C 5°C 0°C
1 atm Room Temp. 30°C Relative Humidity 70% (Dew Pt. 23.09°C)

½” ~ 2″

2½” ~ 5″

6″~ 12″

¾”

1“

1″

⅜“

⅜“

½”

½”

⅝“

⅝“

⅝“

¾”

¾“

¾”

¾“

1“

1 atm Room Temp. 30°C Relative Humidity 80% (Dew Pt. 26.2°C )

½” ~ 2″

2½” ~ 5″

6″~ 12″

1¼”

1¼”

1½”

⅝“

¾”

¾”

¾“

1″

1“

1“

1¼”

1½”

1“

1¼”

1½”

1 atm Room Temp. 30°C Relative Humidity 90% (Dew Pt. 28.2°C)

½” ~ 2″

2½” ~ 5″

6″~ 12″

2″

2“

2½”

1¼”

1½”

1½“

1½”

2“

2“

2″

2“

2½”

2“

2½“

2½”

 

OUTDOOR OF CONDITION O.D. (PIPE)

Skin Temp. of metal surface

-10°C -20°C -40°C -60°C
1 atm Room Temp. 30°C Relative Humidity 70% (Dew Pt. 23.09°C)

½” ~ 2″

2½” ~ 5″

6″~ 12″

1″

1“

1¼”

1¼”

1½”

1½”

1½”

2″

2″

2″

2“

2½”

1 atm Room Temp. 30°C Relative Humidity 80% (Dew Pt.26.2°C)

½” ~ 2″

2½” ~ 5″

6″~ 12″

1¼”

1½“

2“

1½”

2″

2″

2″

2½”

3″

2½”

3“

3½”

1 atm Room Temp. 30°C Relative Humidity 90% (Dew Pt. 28.2°C)

½” ~ 2″

2½” ~ 5″

6″~ 12″

2½“

3“

3½“

3″

3½”

4“

4″

4½“

5“

4½”

5½“

6½“

Thickness Requirement for Tank Insulation:

OUTDOOR OF CONDITION

Skin Temp. of metal surface

90°C 60°C 20°C 10°C 5°C 0°C
1 atm Room Temp. 30°C Relative Humidity 70% (Dew pt. 23.09°C) 1½“

1“

¼” ½” ⅝” ¾”
1 atm Room Temp. 30°C Relative Humidity 80% (Dew pt. 26.2°C)

1½“

1¼”

⅜” ¾” 1¼” 1½”
1 atm Room Temp. 30°C Relative Humidity 85% (Dew pt. 27.2°C)

3½“

1½”

⅝” 1¼” 1½” 2″
1 atm Room Temp. 35°C Relative Humidity 85% (Dew pt. 32.09°C)

4″

2″

1¼” 2″ 2½” 3″
1 atm Room Temp. 30°C Relative Humidity 90% (Dew pt. 28.2°C)

5″

1½”

1″

2″

2½” 3″

 

OUTDOOR OF CONDITION

Skin Temp. of metal surface

-10°C -20°C -40°C -60°C
1 atm Room Temp. 30°C Relative Humidity 70%
(Dew pt. 23.09°C)
1″ 1¼” 2″ 2½”
1 atm Room Temp. 30°C Relative Humidity 80%
(Dew pt. 26.2°C)
2″ 2½” 3″ 4″
1 atm Room Temp. 30°C Relative Humidity 85%
(Dew pt. 27.2°C)
2½” 3″ 4½” 5½”
1 atm Room Temp. 35°C Relative Humidity 85%
(Dew pt. 32.09°C)
4″ 4½” 6″ 7½”
1 atm Room Temp. 30°C Relative Humidity 90%
(Dew pt. 28.2°C)
4″ 5″ 7″ 8½”

Material properties:
1.heat resistance
2.acoustic insulation
3.Nonignitibility
4.thermal insulation
5.avirulence
6.cold resistance
7.acid and alkali resistance
8.water-resistance
9.oil resistance
10.weathering resistance
11.ductility
12.hypertoncity
13.high density
14.Shock resistance
15.Fungus resistance
16.Non-polluting
17.Non-Carcinogenicity
Tags: product