EnglishTraditional Chinese
WORLDWIDE
Facebook
Twitter
YouTube
Skype
Florex Insulation
  • Company Profile
  • Product
    • Colex Insulation Material
      • COLEX Insulation Sheets
      • COLEX Insulation Sleeves
      • PE Foam Tape
      • PE Foam Profile
      • EVA foam Tape
    • Florex Pipe Support
    • Electronic Descaler
    • Nano Photocatalyst
    • Thermal Pad
    • Water Treatment Chemicals
  • Application
    • Electronic Descaler
      • Video
      • Institution
      • Hotel
      • Frozen Factory
      • Industry
      • Laser Cutting Factory
      • Plastic Product Factory
    • COLEX Insulation Sleeves
      • Cold Insulation of COLEX Insulation Sleeve in refrigerant food plant (-50°C)
      • Cryogenic Pipeline -40°C Liquid Ammonia pipeline
      • Liquid Nitrogen Pipeline(-196°C)
      • Failure Examples without Polyethylene foam material
    • COLEX Insulation Sheets
      • Petrochemical Storage Tank
      • Refrigerating Warehouse (-40°C)for seafood
      • Roof Insulation
      • Low Receiver Insulation
    • Florex Pipe Support
  • Installation
    • Colex Insulation Sleeves
    • Colex Insulation Sheets
    • Florex Pipe Support
  • Contact Us
  • News

ALUNER 301 

COOLING WATER SCALE INHIBITOR AND DISPERSANT

ALUNER 301 COOLING WATER INHIBITOR AND DISPERSANT

ALUNER 301 COOLING WATER INHIBITOR AND DISPERSANT

  • Inhibits calcium salts scale formation
  • Disperses suspended solids
  • Effective at ultra low chemical feed levels
  • Maximizes heat transfer
  • Helps keep systems clean, reduces maintenance
  • Provides minimal environmental impact

 

PRINCIPAL USE:

ALUNER 301 is a specifically formulated to maintain clean heat transfer surfaces in once through and re-circulation cooling water systems.  In addition to scale inhibition, ALUNER 301 also provides dispersancy and helps control deposits of mud, silt, and other suspended solids.  ALUNER 301 is compatible with other cooling water treatment programs, including chlorination.

GENERAL DESCRIPTION:

ALUNER 301 is a liquid scale inhibitor/dispersant with the following physical properties:

Color ……………………………… Pale Yellow

Odor ……………………………… Organic

Specific Gravity(at 25°C)………1.04± 0.1

 

DOSAGE:

The dosage of ALUNER 301 is highly dependent on system conditions and scale forming tendency of the water.  Normal dosages for re-circulation systems will range from 50-200 ppm based on blow-down.  Normal dosage for once-through systems will range from 1 to 5 ppm, but higher dosages of ALUNER 301(up to 25 ppm )may be required under extreme scaling conditions.

 

FEEDING:      

ALUNER 301 should be fed to the suction side of the circulation water pumps to ensure adequate mixing.  The product should be fed neat.  Do not dilute.

ALUNER 301 should be fed using stainless steel or plastic feeding equipment. Plastic lined storage tanks are recommended.

 

HANDLING:

KEEP OUT OF REACH OF CHILDREN.  Do not get on skin, in eyes or on clothing.  Do not take internally.  Goggles or face shield are recommended for handling. In case of contact, immediately flush with large amounts of water for at least 15 minutes; for eyes, also get medical attention.  Remove contaminated clothing and wash before reuse.

ALUNER 300
ALUNER 300
ALUNER 309
ALUNER 309

Address :311, TA SHUN 3RD ROAD, KAOHSIUNG, TAIWAN, R.O.C
Tel:886-7-3846968
Fax :886-7-3828047
E-Mail :colex@ms16.hinet.net